This drawing shows the schematic layout of the three busses in our main panel. The busses are called "Panel I" (for "Inverter"), "Panel N" (for "Normal," or maybe "Non-Inverter" depending on when you ask me), and "Panel S" (for "Switched" or "Sharing"). The large power relay switches the feed for "Panel S" between Inverter and Normal power based on a signal from the Automatic Transfer Switch (see separate drawing). The SPDT switch is a manual bypass that can force the connection either way. The 3-in, 3-out rotary switch shown is actually a 3P11T switch (only seven positions used) which allows any pairing of roof airs with the three roof air supply circuits (one on each of the three panels).

This drawing shows the schematic layout of the three busses in our main panel. The busses are called "Panel I" (for "Inverter"), "Panel N" (for "Normal," or maybe "Non-Inverter" depending on when you ask me), and "Panel S" (for "Switched" or "Sharing"). The large power relay switches the feed for "Panel S" between Inverter and Normal power based on a signal from the Automatic Transfer Switch (see separate drawing). The SPDT switch is a manual bypass that can force the connection either way. The 3-in, 3-out rotary switch shown is actually a 3P11T switch (only seven positions used) which allows any pairing of roof airs with the three roof air supply circuits (one on each of the three panels).